X-ray inspection of solder joints produces a density projection, not a cross-section. It shows voids and clear bridges well, but it cannot separate the top row of balls from the bottom row and it often misses a head-in-pillow joint entirely. This applies to offline judgement of BGA and CSP assemblies; the acceptance limit for a void comes from your own process document and the applicable standard edition, not from this page. What follows is what a 2D image can and cannot support, how voids are reported, why the viewing angle changes the answer, and the conditions that justify escalating to CT or electrical test.
A 2D radiograph adds up everything along one ray path. A dark or light region in the image is a sum of solder, copper, substrate and component, so a shape can be real, an overlap of two shapes, or an artefact of the grey window. Interpret it as evidence about density, not as a picture of the joint's surface.
What a 2D BGA image supports, and the condition attached to each conclusion
Feature | What 2D can support | Condition or limit |
Voids inside a ball | Location and relative area of a density deficit | Void must be large enough relative to ball size and image resolution |
Solder bridges | Obvious excess solder between adjacent balls | Only where structures do not overlap along the beam |
Missing or displaced balls | Ball count and gross position | Does not confirm wetting or electrical contact |
Head-in-pillow, non-wet-open | Little or nothing | Needs oblique views, CT or electrical test |
Upper versus lower row of joints | Nothing | Layers are summed into one projection |
The most important consequence is the last row. An image that looks normal is not proof that the joint is electrically sound, and a board can pass X-ray and still fail functional test. That boundary is documented separately in the guide to post-rework functional testing; X-ray and electrical test answer different questions and should both stay in the process.
Report a void as a ratio with its measurement basis, not as a bare percentage. The commonly used figure is the area of the void relative to the projected area of the solder ball, measured on a defined view; some processes report per ball, some report the largest void in a package, and some report a total across the array. Those numbers are not interchangeable.
IPC-A-610 and IPC-7095 provide the vocabulary and the measurement approach used for BGA voiding in assembly acceptance. They do not give your line a universal pass number: the applicable edition, the product class and your customer's process document set that. The site's material on X-ray solder joint inspection covers the imaging basis; keep the acceptance decision in your own procedure.
Two measurement conditions change the result more than most people expect. The grey window used to define the void boundary shifts the measured area, and the magnification changes how many pixels cover a small void. Fix both, record them with the image, and use the same settings when a result is disputed. A percentage quoted without a view, a threshold and a magnification cannot be reproduced by anyone else.
A bridge is only convincing when nothing else along the beam could produce the same shape. In a flat view, two adjacent balls, a via, a copper pour or a ball on the opposite side of the board can overlap into a single dense region that looks like excess solder. Tilting the board changes the ray path and either confirms the connection or splits it into two unrelated features.
That is why the stage matters as much as the detector for this call. Oblique capability, a repeatable tilt angle and enough clearance for the assembly let an operator check a suspicious region at a second angle in seconds. Systems configured for fine-pitch BGA X-ray inspection usually pair a small focal spot with a manipulator for exactly this reason: resolution alone does not resolve an overlap.
Record the angle with the image. A "no bridge" conclusion reached at 0 degrees and one reached at 45 degrees are not the same observation, and a later review that only has the flat image cannot tell which was used.
Head-in-pillow and non-wet-open joints fail 2D inspection because the solder ball and the pad still overlap in projection. The defect is a failure of coalescence at the interface — a gap or an oxide layer with almost no volume along the beam — so the density sum looks much like a good joint. A flat image may show a slightly irregular outline, but that is a hint, not a conclusion.
Three routes can settle it. Oblique views sometimes reveal the separation at the interface; CT separates the layers in a reconstructed volume; electrical test confirms whether the connection conducts. Which one is appropriate depends on whether you need to see the geometry or just decide the board. The seven defect scenarios set out the cases where imaging rather than a simple pass/fail is warranted.
Do not train an operator to "read" head-in-pillow from a flat grey shape. If the process has seen this failure mode, write the escalation route into the inspection instruction with a trigger — a suspect outline, a known component lot, or a functional failure — so the decision does not depend on one person's confidence.
A repeatable read is a fixed set of conditions plus a fixed record, not a skilled guess. You can build it without any supplier data: choose one representative board, define the views, and keep a reference image set for good and rejected joints at those settings.
Fix tube voltage, current, magnification and the grey window for each board type; record them on the reference image.
Define the views in order — flat first, then the oblique angles used for suspect regions — and note the tilt used for each.
Define what is recorded for every call: board ID, package location, view, void ratio with its measurement basis, and the operator's conclusion.
Keep accepted and rejected examples side by side, and re-issue the reference set whenever exposure conditions or the board revision change.
Review disagreements against the reference set, not against the person who made the call.
Once that record exists, a second operator can reproduce a judgement and a drift in the imaging chain becomes visible as a difference from the baseline rather than as an argument about interpretation.
Escalate when the question needs depth, or when the question is electrical. CT is the right step when you must locate a defect in a volume, separate two rows of joints, or document an internal geometry for a failure report. The specification logic for such a system — voxel size, sample fit, reconstruction time — is covered in the guide to the industrial CT scanner product family. CT is slow, so use it on sampled parts or on a specific suspect board.
Electrical test is the right step when the image is clean but the board does not work, or when the failure mode is an open or marginal connection that radiography cannot see. Neither method replaces the other: CT tells you where the geometry went wrong, functional test tells you whether the assembly performs. Write both triggers into the instruction — "suspect overlap that a second angle cannot resolve" for CT, "X-ray pass with functional failure" for electrical test — so escalation is a rule rather than a debate.
No. The acceptable limit depends on the applicable standard edition, product class and your customer's process document. IPC-A-610 and IPC-7095 give the measurement language, not a universal number. Record the void ratio with its view, threshold and magnification so the result can be checked against whatever criterion applies.
Usually not on its own. Joints on opposite sides share ray paths, so a flat image sums them. You need oblique views at minimum, and CT where the layers genuinely have to be separated. Decide this from the board stack-up before choosing a machine.
Board and package identification, the views and tilt angles used, exposure settings and grey window, the void ratio with its measurement basis, the conclusion, and the operator. Those fields let someone else reproduce the call and make a later image comparison meaningful.
IPC-A-610 and IPC-7095 for acceptance and measurement language on solder joints and BGA voiding. Use the edition cited in your own quality system; no acceptance limit is stated in this article.
Seamark ZM published product pages: microfocus X-ray inspection machine, X6600 offline X-ray inspection system, industrial microfocus 3D CT machine.
Internal guides on this site: X-ray inspection equipment in SMT processing, basic principles of PCB X-ray imaging, post-rework functional testing, and the defect scenarios that may require 3D CT.