The useful way to sort the types of X-ray machines on the market is by what you need to see, not by the name on the cabinet. Counting reels, checking BGA joints, reconstructing internal structure, judging boards inline and examining welds or castings are five different jobs, and one machine rarely does all five well. This page applies when a line has both counting and inspection needs, or when a buyer has to decide between 2D radiography, 3D CT, inline AXI and industrial radiography. It gives the condition that makes each type sufficient, the hardware that follows from that condition, and the cases where the type is the wrong purchase. Prices, supplier lists and brand rankings are not covered here.
Start with the object, because the object fixes the geometry. A reel of components needs a count, not an image a person interprets; a BGA needs a projection through solder; a casting needs penetration through millimetres of metal; an inline board needs a decision at line speed. Five paths follow from that split, and each one has a different failure mode.
Count. The output is a number with a reel ID, not a radiograph. An X-ray counting machine reads the reel and hands the result to inventory control.
Joints on an assembly. The output is an image an operator or algorithm judges: voids, bridges, missing balls, open joints.
Internal structure in three dimensions. The output is a volume, sliced or reconstructed, where depth matters more than contrast.
Judgement at line speed. The output is a pass or fail attached to a board, produced without an operator stopping the line.
Volume defects in metal. The output is a radiograph of a weld or casting, assessed against an image-quality requirement.
The split holds only while the jobs stay separate. It breaks down as soon as someone expects a counter to inspect solder joints, or a 2D inspection cabinet to reconstruct a double-sided board. A wider description of X-ray systems by imaging method is useful background, but it does not replace this decision: imaging method and inspection job are not the same axis.
2D radiography is enough when the defect has enough density contrast against its surroundings and the structures along the beam do not overlap in a way that hides it. A single-sided board, a thin assembly, a coarse-pitch BGA with clear voids, or a simple go/no-go check on a connector: all of these are normally settled with a flat image and a fixed set of exposure conditions.
The condition is worth stating precisely, because it is also the boundary. A 2D image is a density projection. Everything between the source and the detector is added into one grey value, so two features at different depths can look like one feature, and a small void can disappear under a dense shield can. Where that overlap is absent, an industrial X-ray machine with a well-chosen tube and detector is usually the simpler tool: fewer moving parts, a shorter cycle, and an operator who can be trained on a small set of reference images.
Keep the exposure conditions fixed once they work. Most apparent "inspection drift" on a 2D system turns out to be a changed tube current, a changed magnification or a changed grey window, not a changed process. Recording those three settings with the reference image costs nothing and makes the next dispute much shorter.
Move to CT when the question has a depth component, and to inline AXI when the question has a time component. These are different triggers, and buying for the wrong one is a common and expensive mistake.
CT is required when a defect can only be located or sized in a volume: a void inside a solder ball that a projection cannot separate from the ball above it, a head-in-pillow joint where the solder and the pad never coalesced, an internal crack in a casting, or any feature hidden behind another dense layer. The cost is time. A CT scan acquires many projections and reconstructs them, so a single part takes far longer than a single radiograph. An industrial CT scanner therefore earns its place in failure analysis, sampling and laboratory work rather than in 100 percent inspection of a fast line.
Inline AXI is required when the decision must be made without an operator and without stopping the conveyor. The trigger is takt time and the need for a repeatable, logged judgement, not image quality. AXI still produces 2D or 2.5D projections on most lines; the difference is that the algorithm, the handling and the board tracking are part of the machine. The seven defect situations where a flat view stops being adequate are documented separately on this site; this page only decides which family you should be looking at.
Once the job is fixed, the hardware choices stop being a shopping list and become consequences. Four fields on a specification sheet change meaning depending on the path:
Tube voltage and power. Set by the densest material and the thickest section in the beam, not by the smallest feature. Plastic-encapsulated components and thin boards sit at the low end; aluminium castings and steel welds need substantially more penetration.
Focal spot. Set by the smallest feature you need to resolve at the magnification you actually use. A small spot only helps if geometric unsharpness is the limiting factor; on a thick casting, penetration dominates long before spot size does.
Detector. Set by the trade-off between field of view, pixel pitch and contrast. A fine pixel over a small area suits a BGA; a large-area detector with lower resolution suits a weld seam where coverage matters more.
Stage and manipulation. Set by whether the part must be tilted, rotated or scanned through many angles. Counting reels needs repeatable positioning, CT needs a rotation stage with known geometry, and weld work needs room for an awkward part and an image-quality indicator.
Notice that "higher" is not a direction here. Raising tube voltage improves penetration and reduces contrast; reducing focal spot improves detail and reduces flux; increasing detector resolution shrinks the field of view. A specification sheet that lists large numbers in all four columns without naming the inspection target is describing a machine, not a fit.
Each of the five paths has a published page on this site, so the classification can be checked against real specifications rather than against a category name.
Inspection job, machine type, and the condition that rules the type out
Inspection job | Machine type | What it must deliver | Rule-out condition |
Reel count | X-ray component counter | Quantity plus reel ID, tied to inventory | Asked to judge solder-joint quality |
PCBA joints, offline | 2D offline cabinet | Repeatable projection image at fixed settings | Overlapping double-sided assemblies |
Internal volume | 3D CT system | Reconstructed slices with depth information | Inline 100 percent inspection at short takt |
Inline judgement | Inline AXI | Automatic pass or fail with board tracking | Low volume, many product changeovers |
Welds and castings | Industrial radiography system | Penetration plus demonstrated image quality | Planar defects unfavourably oriented to the beam |
The offline and inline cabinets are described on the PCB X-ray inspection pages, and the casting branch is represented by X-ray casting inspection equipment built for thicker sections. Read those pages for tube, detector and stage figures; the table above only tells you which page to open first.
Three constraints eliminate a machine type before any specification is compared: takt, footprint and maintenance capability. A CT system that needs minutes per part cannot sit behind a conveyor running one board every few seconds, however good the reconstruction. An inline AXI station needs conveyor integration, board handling and a stable product mix; a job shop with a new board every hour will spend more time on changeover than on inspection. A high-end microfocus system is a poor fit where nobody on site can maintain a baseline image or recognise detector drift.
The honest exclusion rule is this: if the failure mode you care about is planar and oriented unfavourably to the beam, radiography is the wrong method, not the wrong model. Ultrasonic testing, dye penetrant or electrical test may answer the question that an X-ray image cannot. Once the path is fixed, open the matching product page and check the tube, detector and stage figures against your own largest part and your smallest defect; that comparison, not a category label, is what should drive the shortlist.
Not well. A counter is built to read a reel quickly and return a quantity, with handling optimised for reels and a software path into inventory. An inspection cabinet is built to produce a diagnosable image of an assembly. Sharing a source and detector does not make the optics, fixturing or output the same, so plan for separate equipment when both jobs exist on the line.
No. Inline wins when every board must be judged at line speed and the product mix is stable. Offline wins when you need magnification, tilting, multiple exposures or an operator's interpretation. If most of your work is failure analysis or low-volume sampling, an inline station adds cost and changeover work without adding judgements you need.
No. Counting uses the attenuation pattern of components on a reel to estimate quantity; it does not resolve solder-joint shape, voids or bridges on an assembled board. Treat counter output as an inventory figure and keep a separate inspection path for assembled joints.
Seamark ZM product pages: offline and online X-ray inspection machines, industrial microfocus 3D CT, X-ray SMD reel counter, XD160 precision casting inspection equipment. Specifications are quoted from those published pages; check the live page before specifying a machine.
IPC-A-610 and IPC-7095 for acceptance language on solder joints and BGA voids; ISO 17636 series and ASTM E1032 / E505 for radiographic practice and image quality. Use the edition cited in your own quality system, not the edition quoted in a supplier brochure.
Internal guides on this site: types of X-ray imaging systems, choosing between online and offline X-ray inspection equipment, and the seven defect scenarios that may require 3D CT.